Figure 18 rear wall girt installation check the framework is square and level before fixing rear wall girts. Longspan metal roofing stramit longspan roof hmr supplies. All you need to know about stramit products and services available in your area. To guide users through installation, stramit has created a four part video series. Part of the stramit architectural range, sharpline cladding is a modern, versatile solution that seamlessly integrates with other building products. The standard range of purlin products available is. Where required for structural or installation purposes, stramit bridging shall be installed using premade components to manufacturers instructions.

Stramit bridging shall be installed using premade components to manufacturers instructions. The sheeting shall be fixed to the purlins girts in accordance with the manufacturers recommendations. Stramit s sharpline architectural cladding forms a visually striking profile with tall, sharp ribs and flat pans. Stramit fascia gutter is a square feature gutter providing a clean appearance and the strength advantages of a stiffened back. Stramit monolap roof lap joint units can only be installed on roofs designed for its use. Architectural steel cladding sharpline by stramit building. Please contact stramit to discuss your specific project requirements. We intend that it be used by all trades and professions involved with specifying and applying the wide range of our products.

Hole for roof purlin hole for roof purlin rafter m12x30mm high tensile bolts eaves bracket column note. This simple change, enabled by stramit s stateoftheart. Sharpline cladding can be installed vertically, horizontally or diagonally to create numerous design options for wall cladding and roofing profiles. It has a square face for easy mitres and installation is fast with snap clips and stiffeners. We have a range of information to help you select the right products for your job, from architectural drawings through to technical, design and installation manuals. The gutter has excellent watercarrying capacity and can be supplied slotted for additional overflow protection. Lysaght fascia purlins incorporate many design features which make it an easytouse, economical eave purlin and fascia combined. Stramit exacta purlins product technical manual selector.

The gutter has a large water carrying capacity and a high front with overflow slots if required to conceal the edge of the roofline. Stramit purlins girts and bridging product technical manual this technical manual is a comprehensive guide to selecting and specifying stramit purlins girts and bridging and incorporates limit state design capacities based on the latest software specifically developed for purlins and girts at sydney university. Application metroll megaspan purlins and girts are primarily used in. Tables have been prepared using software developed for stramit by the university of sydney. Stramit monolap roof lap rolls for supply with stramit monoclad cladding can be ordered from your nearest stramit location or distributor of stramit products. Diagram shows columns cut back for an onconcrete shed. The combination is an attractive fascia gutter solution that is straight and true. The guide contains details on all stramit purlins, girts, bridging and relevant accessories.

All sections shall be produced from galvanised steel to as97 with a coating mass of at least. Place top fixing clips over each squashed male rib and fix to the purlins figure 5. Megaspan is a higher performance section, standard purlins will not deliver the same load capacities and may be underengineered and potentially unsafe. Silvercote certifies that when the purlin glide fp system is installed by a silvercotecertified contractor and in strict confo r mance with silvercotes instructions, the purlin glide fp system provides leading edge fall prevention in compliance with cfr 1926. Stramit monopanel cladding is an attractive, durable system of interlocking panels with concealed fixings. Residential steel walling by stramit building products. Bluescope steel limited does not warrant the accuracy or currency of the content and is not responsible or liable for content provided by third parties. The advanced design ensures reliability and ease of construction. Stramit corrugated cladding sheeting mass kgm2 of roof area thickness bmt grade zincalume colorbond galvanised 0.

Series a roller door installation instructions page 5 issue date 12th october, 2015 product warranty stramit corporation pty limited roller door warranty and exclusion of liability statement 1. Wider portal frame spacings have created a need for long length, one piece fascia purlins. In addition a comprehensive purlin test programme at sydney university has been. Purlin installation purlins are bolted to the primary frame by way of cleats welded to rafters or columns by a qualified steel fabricator. Spans may exceed those shown in this table, provided the wind pressure and foot traffic limits are not exceeded. For more specific applications stramit speed deck ultra decking must be designed to the pressure and foot traffic limitations below.

Stramit offers a complete range of custom rainwater goods and roofing accessories to suit almost any architectural style. Where required for structural or installation purposes. Stramitpurlinsgirtsandbridgingproducttechnicalmanual. Ask your nearest stramit location for colour availability. Like galvanised steel, it can be welded, touched up using zincrich paint and, if required, postpainted or decorated in the same way as galvanised steel.

Tolerances all sections will be produced within the following tolerances. Stramit purlins girts and bridging detailing and installation. When commencing installation of the building, the first braced bay must be erected with all the bracing, eave struts, purlins, girts and flange braces completely installed and all bolts properly tightened to make certain that the building is properly braced. Zam coated steel has a bright, uniform appearance that ages to a satinlike metallic finish. View stramit purlins girtsandbridgingproducttechnical manual. Roof lap joint system for stramit monoclad roof cladding. Sharpline cladding is available in complementary colours and finishes to create a subtle or bold statement against other facade elements. As well as the standard range of product technical manuals, installation leaflets, case studies and other promotional literature, stramit has a series of guides to aid design. Stramit triline sb stiffened back gutter was designed for the home improvement market and is suitable for fascia or patio applications. Stramit purlins and girts have a z350 zinc coating and are available in an extensive range of sizes. Section properties for different purlin configurations can be found in the downloadable manual.

Where required for structural or installation purposes, materials stramit bridging shall be installed using premade components to manufacturers instructions. The latter enables engineers to input properties and capacities into their preferred structural analysis software. For the remaining purlin spaces 48 or greater, install two bands per space. Position and fix the first sheet ensuring the correct sheet overhangs minimum 50mm. Architectural specification this specification can be found on the stramit web site and can be easily downloaded onto your documentation. With wide cover for quick installation and easy handling, stramit corrugated sheeting suits traditional and modern home designs and is available in a full range of colours. In this video, well show you how to install stramit bridging on a roof, in one possible way called downtheslope. Information is provided to enable detailed purlin design including a wide range of practical component assemblies to cover almost all applications. Stramit fascia is suited to a broad range of stramt gutters and a range of accessories are available for easy installation. Stramit s range of steel wall cladding for residential applications is lightweight, strong, attractive and suited to many design applications. Stramit premier 300 architectural cladding steel select. Steel purlins and girts by stramit building products selector.

To enhance purlin performance and to assist with the erection of roof sheeting, stramit recommends that bridging be installed such that the maximum unbraced length is 20 x d where d is the purlin web height,or 4000mm whichever is the least. Stramit premier 300 architectural cladding is lightweight, easy to install and instantly adds architectural style to any commercial project or new home. Stramit fascia is available in a range of colorbond steel colours and finishes. New south wales designers must refer to the new south wales lysaght supazed and lysaght supacee purlins and girts range. Rollformed from hightensile australianmade steel, galvanised for corrosion protection, these fascia purlins can be. Our handy tips on ordering, loading, deliveries even takeoff estimates are also available to help make life easier for you.

Monolap joint is installed over a supporting purlin. For this reason a maximum bridging or bridging to cleat spacing of. Stramit bridging conforms to aisc standards for hole size and hole centres for 100mm to 250mm purlins. With a felttipped pen, make a small mark in the pan to enable you to locate the clips in the later locking operation with the button punch figure 6. These capacities are based on the mass of the girts plus a 1. Stramit purlin accessories are designed for full compatibility with stramit purlins and girts. Testing stramit research and development has carried out numerous inhouse tests at its rydalmere complex on both purlins andor girt bridging. All other purlin accessories shall be supplied by stramit. Our october 2020 edition of the product and service guide is available in our new digital format to make it easier to access for all our customers, no matter where youre working. Standard purlins must not be substituted for designs using information from this megaspan design manual. The girts should be at the same level as side wall purlins. Accessories like brackets and bolts are also available.

A list of all available metroll resources and brochures available. Applications australian design mark speed deck ultra no. Ensure all purlins are in line and correctly installed and that mesh and blanket if specified are in place. Cleats and the associated hole geometry are detailed in aisc standardised structural connections manual. Deliveryunloading delivery can normally be made within 48 hours, subject to the delivery location, quantity and material. All purlins and girts shall be stramit sections or approved equivalent, supported by submission of section properties, purlin capacity calculations, bridging capacity calculations and a performance warranty, produced and detailed for this project.

Residential steel walling by stramit building products selector. Other coatings, grades and materials may be available, subject to inquiry. This simple change, enabled by stramit s stateoftheart manufacturing equipment and. Integrated bridging boltless design specifically for stramit sections. Contact your local sales office for product availability. This aesthetically pleasing panelling combines the traditional beauty of flat panels with the strength and durability of steel.

768 1160 1115 561 47 81 1433 703 509 764 124 104 510 318 1242 1367 1126 905 670 106 86 472 1347 448 2 604 296 1173 990 1232 1165